Pre-Summer Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65pass65

CDCP Certified Data Centre Professional (CDCP) is now Stable and With Pass Result | Test Your Knowledge for Free

Exams4sure Dumps

CDCP Practice Questions

Certified Data Centre Professional (CDCP)

Last Update 6 hours ago
Total Questions : 88

Dive into our fully updated and stable CDCP practice test platform, featuring all the latest EPI Data Centre exam questions added this week. Our preparation tool is more than just a Exin study aid; it's a strategic advantage.

Our free EPI Data Centre practice questions crafted to reflect the domains and difficulty of the actual exam. The detailed rationales explain the 'why' behind each answer, reinforcing key concepts about CDCP. Use this test to pinpoint which areas you need to focus your study on.

CDCP PDF

CDCP PDF (Printable)
$43.75
$124.99

CDCP Testing Engine

CDCP PDF (Printable)
$50.75
$144.99

CDCP PDF + Testing Engine

CDCP PDF (Printable)
$63.7
$181.99
Question # 11

What are the four main components of a refrigeration circuit?

Options:

A.  

Evaporation, membrane filter, monitor sensor, pressure valve

B.  

Evaporator, compressor, condenser, expansion valve

C.  

Condenser, expansion valve, buffer tank, de-icing unit

D.  

Thermostat, monitoring interface, indoor unit, outdoor unit

Discussion 0
Question # 12

Which one of the following is an example of Indirect Cost?

Options:

A.  

Legal fees

B.  

Damaged brand perception

C.  

System recovery

D.  

Cost revenues

Discussion 0
Question # 13

systems are designed specifically to protect the structure of a building.

Options:

A.  

Pro-inert

B.  

Inergen

C.  

Water sprinkler

D.  

Total Flooding

Discussion 0
Question # 14

What is the recommended location for the Isolation Transformer in relation to the ICT-Equipment location?

Options:

A.  

The isolation transformer should be as close as possible to the ICT equipment but taking into account potential EM

F.  

B.  

The isolation transformer should be as far away as possible to the ICT equipment to avoid potential EM

F.  

C.  

The isolation transformer has to be installed within the power entry point of the building due to electrical code (regulation) requirements.

D.  

The isolation transformer should be installed within the rack in which the ICT equipment has been installed.

Discussion 0
Question # 15

Looking from within the Computer room, what should the door-swing (opening) direction be?

Options:

A.  

Outwards, code permitted

B.  

Instead of swinging doors, sliding doors are preferred

C.  

Depends on the type of Computer room

D.  

Inwards, code permitted

Discussion 0
Question # 16

What is the purpose of a service corridor?

Options:

A.  

To create a secure and conditioned environment where media can be stored in a controlled manner.

B.  

It is a generic name for pathways leading to other rooms that contains facility supporting equipment like the UPS room, battery room, generator room etc.

C.  

It provides a safe, vented and secure area where standby generators can operate safely.

D.  

It provides a secure area where supporting facilities can be serviced and monitored on a 24x7 basis without disturbing the computer room.

Discussion 0
Question # 17

What is a disadvantage of a Dynamic UPS?

Options:

A.  

They are heavy and more noisy.

B.  

It needs a separate back-up generator as their autonomy time is less than 60 seconds.

C.  

It needs additional cooling infrastructure as high temperatures reduces the lifetime of a Dynamic UPS.

D.  

They are only available for small to medium sized data centres, due to their limited capacity of 200 kVA

Discussion 0
Question # 18

Escape route signage should be placed where?

Options:

A.  

Only at emergency escape doors

B.  

Only at the main entrance of the data centre building

C.  

At every door providing a pathway

D.  

At every door including riser doors, doors of storage closets etc.

Discussion 0
Question # 19

When referring to the internal mounting space in racks, equipment manufactures generally refer to standardized height of electronic modules “U” or “RU”. What is the height of 1 “U” or “RU”?

Options:

A.  

19 inches (60 cm)

B.  

24 inches (80 cm)

C.  

1.75 inches (4.445 cm)

D.  

3.5 inches (8.59 crn)

Discussion 0
Question # 20

Which one of the following is the last stage in Stages of Combustion?

Options:

A.  

Visible Smoke

B.  

Intense Heat

C.  

Incipient

D.  

Flaming Fire

Discussion 0