Exclusive Black Friday Deal: 75% Off All Exam Bundles! Use coupon code below to unlock your savings! - Ends in 0d 00h 00m 00s - Coupon code: e4s75best

Free Tech in Surgery - Certified (NCCT), TS-C (NCCT) Practice Questions

Question # 11

Which of the following contains the information necessary to gather all items for a surgical case?

Options:

A.  

Surgeon ' s preference card

B.  

Instrument count sheet

C.  

History and physical

D.  

Surgical checklist

Discussion 0
Question # 12

With regard to the use of a fire extinguisher, what does PASS stand for?

Options:

A.  

Pull, Aim, Squeeze, and Swipe

B.  

Pull, Alert, Squeeze, and Sweep

C.  

Pull, Aim, Squeeze, and Sweep

D.  

Push, Aim, Squeeze, and Sweep

Discussion 0
Question # 13

A surgical technologist is opening instrument trays. No internal chemical indicator strip is found inside a well-wrapped, dry instrument pack. There are no holes or visible defects in the double-layered outer wrap. Which action should the surgical technologist take?

Options:

A.  

Check the indicator tape on the wrap.

B.  

Use the instruments in the tray.

C.  

Request a chemical indicator strip from central supply.

D.  

Obtain a new tray containing an internal chemical indicator strip.

Discussion 0
Question # 14

Which of the following is the MOST common source of ignition in the operating room?

Options:

A.  

Argon lasers

B.  

Electrosurgical generators

C.  

Alcohol-based preparations

D.  

Heat lamps

Discussion 0
Question # 15

When performing a 10-minute gravity-displacement steam sterilization cycle, what is the appropriate temperature range?

Options:

A.  

220–230°F

B.  

270–275°F

C.  

250–255°F

D.  

290–300°F

Discussion 0
Question # 16

When setting up for the first surgical case of the day, what should be the FIRST item on the surgical technologist ' s checklist?

Options:

A.  

Wipe down the operating room with soap and water.

B.  

Make sure all equipment is present for the case.

C.  

Open sterile supplies for the procedure.

D.  

Make sure the surgical lights are functioning.

Discussion 0
Question # 17

A prevacuum steam sterilizer ' s printout indicates that the temperature, pressure, and exposure-time requirements were met during instrument sterilization. The Bowie-Dick test also showed satisfactory results. Four hours after the load was processed, the biological indicator reveals a positive result. Which action should the surgical technologist take?

Options:

A.  

Treat the biological indicator as defective and use a different lot number of biological indicators during the next sterilization cycle.

B.  

Treat the biological indicator as accurate and use the sterilized supplies from the load.

C.  

Treat the biological indicator as defective and use the sterilized supplies from the load.

D.  

Treat the biological indicator as accurate and recall the sterilized items from the load.

Discussion 0
Question # 18

While the surgeon is performing blunt dissection during an abdominal procedure, it becomes necessary to ligate a vessel before continuing the dissection. Which sequence of steps should the surgical technologist anticipate NEXT?

Options:

A.  

Tie, clamp, clamp, cut

B.  

Clamp, tie, cut

C.  

Tie, clamp, cauterize

D.  

Clamp, clamp, cut, tie

Discussion 0
Question # 19

Which of the following is the MOST common retraction instrument found in gynecological surgical trays?

Options:

A.  

Wright speculum

B.  

Pederson speculum

C.  

Graves speculum

D.  

Lucy speculum

Discussion 0
Question # 20

Which of the following sutures has the LARGEST diameter?

Options:

A.  

#1

B.  

#5

C.  

5-0

D.  

0

Discussion 0

TS-C PDF

TS-C PDF (Printable)
$41.25
$164.99

TS-C Testing Engine

TS-C PDF (Printable)
$45
$179.99

TS-C PDF + Testing Engine

TS-C PDF (Printable)
$55.75
$222.99

Free Exams Sample Questions