Pre-Summer Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65pass65

300-615 Troubleshooting Cisco Data Center Infrastructure (300-615 DCIT) v1.1 is now Stable and With Pass Result | Test Your Knowledge for Free

Exams4sure Dumps

300-615 Practice Questions

Troubleshooting Cisco Data Center Infrastructure (300-615 DCIT) v1.1

Last Update 1 day ago
Total Questions : 221

Dive into our fully updated and stable 300-615 practice test platform, featuring all the latest CCNP Data Center exam questions added this week. Our preparation tool is more than just a Cisco study aid; it's a strategic advantage.

Our free CCNP Data Center practice questions crafted to reflect the domains and difficulty of the actual exam. The detailed rationales explain the 'why' behind each answer, reinforcing key concepts about 300-615. Use this test to pinpoint which areas you need to focus your study on.

300-615 PDF

300-615 PDF (Printable)
$54.25
$154.99

300-615 Testing Engine

300-615 PDF (Printable)
$59.5
$169.99

300-615 PDF + Testing Engine

300-615 PDF (Printable)
$74.55
$212.99
Question # 21

A maintenance operation on power rail A caused a reboot of the servers in a Cisco UCS B-Series chassis. The Cisco UCS system has these attributes:

* The system is equipped with four PSUs.

* N+1 mode is used.

* PSU 1 and 2 are connected to rail

A.  

* PSU 3 and 4 are connected to rail

B.  

Which action prevents server reboot when rail A goes down?

Options:

A.  

Configure nonredundant mode with PSU1 and 3 on A and PSU2 and 4 on

B.  

B.  

Use GRID mode; do not change physical plugs.

C.  

Configure N+1 mode with PSU1 and 2 on B and PSU3 and 4 on

A.  

D.  

Use N+2 mode; do not change physical plugs.

Discussion 0
Question # 22

Refer to the exhibit.

Question # 22

Cisco UCS Manager is being upgraded using the Auto Install feature, but the FSM fails. Which action resolves the issue?

Options:

A.  

Acknowledge the primary fabric interconnect.

B.  

Remove the service pack from the subordinate fabric interconnect.

C.  

Clear the startup version of the default infrastructure pack.

D.  

Upgrade the firmware of the infrastructure firmware by using the force option.

Discussion 0
Question # 23

Question # 23

Refer to the exhibit A network engineer fails to boot a Cisco UCS blade from SAN The data center uses Cisco UCS B-Series blades with the end-host mode configured on Cisco UCS fabric interconnects The storage administrator reports no issues with the array Winch action resolves the issue?

Options:

A.  

Change zoning on the Cisco UCS side.

B.  

Modify zoning on the upstream switch.

C.  

Unmask the LUN on the storage array

D.  

Remove the LUN ID from the boot policy

Discussion 0
Question # 24

The Cisco Nexus switch is connected to a peer switch that is not running Cisco NX-OS. The switches are connected using port channel and are experiencing packet loss. Which action should be performed on the Cisco Nexus switch ports to resolve this issue?

Options:

A.  

Turn on lacp suspend-individual.

B.  

Turn on lacp graceful-convergence.

C.  

Turn off lacp graceful-convergence.

D.  

Turn off lacp suspend-individual.

Discussion 0
Question # 25

A host connected to port Eth0/1 on the Cisco Nexus Series Switch received this error

*Mar 6 12 57 42 882 %PM-4-ERR DISABLE psecure-violation error detected on Eth0/1, putting Eth0/1 in err-disable state-Mar 6 12 57 42 882 %PORT_SECURITY-2-PSECURE_VIOLATION Security violation occurred, caused by MAC address a526 cc69 3503 on port EthernetO ' 1.

The server administrator concluded that the issue was caused by plugging the host in the wrong switch port and fixed the problem Which action must be taken to recover the port from the error?

Options:

A.  

Install ENHANCED_LAYER2_PKG license

B.  

Enable NET\V0RK_SERV1CES_PKG license.

C.  

Shut and no shut the interface Eth0/I.

D.  

Change the interface Eth0/1 mode to access

Discussion 0
Question # 26

A Cisco Nexus 9000 Series Switch crashes and fails to boot. An engineer must recover the switch and investigate the issue. The switch uses 172.20.50.213/24 IP address for management and its default gateway is 172.20.50.254. Drag and drop the steps for recovering the Cisco Nexus 9000 Series Switch from the left onto the right. Not all steps are used.

Select and Place:

Question # 26

Options:

Discussion 0
Question # 27

Refer to the exhibit.

Question # 27

A network engineer is implementing a Cisco UCS environment. The environment consists of eight servers configured with the same service profile template and Windows 2012 installed. The VFC interfaces of five of these servers are showing the error shown in the exhibit. Which action resolves the issue?

Options:

A.  

Modify the vHBAs name in the storage connectivity policy

B.  

Configure upstream zoning

C.  

Decommission and recommission the servers

D.  

Modify the boot order in the boot policy

Discussion 0
Question # 28

Refer to the exhibit.

Question # 28

The EEM script fails to send an SNMP trap when a user attempts to enter configuration mode. Which configuration is missing from the script?

Options:

A.  

event statement

B.  

event-default action statement

C.  

policy-default action statement

D.  

IP address of the SNMP server

Discussion 0
Question # 29

Question # 29

Refer to the exhibit. An engineer troubleshoots an OSPF neighborship problem between Router R2 and Router R10. Which action resolves the problem?

Options:

A.  

Change area ID on Router R10

B.  

Resolve unicast reply from Router R2

C.  

Resolve authentication type on Router R10

D.  

Change router ID on Router R10

Discussion 0
Question # 30

Refer to the exhibit.

Question # 30

The HSRP configuration in the exhibit fails to function. Which action resolves this issue?

Options:

A.  

Enable IP redirects.

B.  

Set the MTU to 1500 bytes.

C.  

Configure HSRP version 2.

D.  

Configure the same HSRP group on both devices.

Discussion 0
Get 300-615 dumps and pass your exam in 24 hours!

Free Exams Sample Questions