Pre-Summer Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65pass65

300-615 Troubleshooting Cisco Data Center Infrastructure (300-615 DCIT) v1.1 is now Stable and With Pass Result | Test Your Knowledge for Free

Exams4sure Dumps

300-615 Practice Questions

Troubleshooting Cisco Data Center Infrastructure (300-615 DCIT) v1.1

Last Update 1 day ago
Total Questions : 221

Dive into our fully updated and stable 300-615 practice test platform, featuring all the latest CCNP Data Center exam questions added this week. Our preparation tool is more than just a Cisco study aid; it's a strategic advantage.

Our free CCNP Data Center practice questions crafted to reflect the domains and difficulty of the actual exam. The detailed rationales explain the 'why' behind each answer, reinforcing key concepts about 300-615. Use this test to pinpoint which areas you need to focus your study on.

300-615 PDF

300-615 PDF (Printable)
$54.25
$154.99

300-615 Testing Engine

300-615 PDF (Printable)
$59.5
$169.99

300-615 PDF + Testing Engine

300-615 PDF (Printable)
$74.55
$212.99
Question # 1

Refer to the exhibit.

Question # 1

An engineer is configuring boot from iSCSI on a Cisco UCS B-Series Blade Server, but the LUN fails to mount. Which action resolves the issue?

Options:

A.  

Statically configure the target information in the Boot Policy.

B.  

Configure an MTU size of 9000 on the appliance port.

C.  

Configure a QoS policy on the vNI

C.  

D.  

Set a connection timeout value of 250 in the iSCSI Adapter Policy.

Discussion 0
Question # 2

A network engineer discovers a DNS resolution problem on a device that is using the Cisco Nexus Bash shell.

The device name is app with an IP address of 10.10.10.1. The primary server IP address is 172.16.10.1 and

the secondary server IP address is 172.16.10.2. When the abc.com resolution fails, it should attempt to use

efg.com. Which settings must be added to resolv.conf file to resolve the issue?

Question # 2

Options:

A.  

Option A

B.  

Option B

C.  

Option B

D.  

Option D

Discussion 0
Question # 3

Refer to the exhibit.

Question # 3

vPC between switch1 and switch2 is not working. Which two actions are needed to fix the problem? (Choose two.)

Options:

A.  

Match vPC domain ID between the two devices.

B.  

Configure IP address on the interface.

C.  

Activate VLANs on the vP

C.  

D.  

Configure vPC peer link and vPC peer keepalive correctly.

E.  

Configure one of the switches as primary for the vP

C.  

Discussion 0
Question # 4

Refer to the exhibit.

Question # 4

A PC belongs to VLAN 68 The user experiences a large amount of packet loss when communicating with hosts that are outside of VLAN 68. Which action resolves the problem?

Options:

A.  

Replace HSRP with GLBP

B.  

Enable the peer-gateway feature

C.  

Remove the HSRP configuration

D.  

Configure ip arp synchronization on both switches.

Discussion 0
Question # 5

Refer to the exhibit.

Question # 5

An engineer uses a REST API to map the interface selector with ports 1/1 to 1/20 to an interface profile. The script fails with a 400 response status code. Which action resolves the problem?

Options:

A.  

Permit user access to the requested resource.

B.  

Post the script using the HTTPS method.

C.  

Add a content-length header to the request.

D.  

Run the script again with valid authentication values.

Discussion 0
Question # 6

A customer reports that the Chassis Management Controller fails to receive chassis information from Cisco UCS Manager. Which set of steps resolves the issue?

Options:

A.  

1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels

2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.

3) Check for runtime link down status

4) Reseat the affected IOM.

B.  

1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.

2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.

3) Check for runtime link down status

4) Reseat the affected IOM.

C.  

1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.

2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.

3) Check for runtime link down status.

4) Reseat the affected IOM.

D.  

1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels.

2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.

3) Check for runtime link down status.

4) Reseat the affected IOM.

Discussion 0
Question # 7

Question # 7

Refer to the exhibit. A network engineer is configuring the FCoE N_Port virtualization storage area network. After the initial implementation, server 11 fails to connect to the disk array. Which action resolves the issue?

Options:

A.  

On MDS interface vfc 1/1, change switchport mode configuration to VF

B.  

On N9K interface vfc11, change switchport mode configuration to NP

C.  

On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to F

D.  

On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to E

Discussion 0
Question # 8

An engineer configures FCoE between a set of ESXi hosts and a Cisco Nexus 5000 Series Switch. The Converged Network Adapter of the host fails to receive the response from the Cisco Nexus device. Also, the VFC interface is in a down state and the FIP adapter fails to receive 802.1q tagged frames. The host interface is configured for VLAN trunking. Which action resolves the issue?

Options:

A.  

Activate the reception of Xoff pause frames from the server

B.  

Configure the UF link as a spanning-tree edge port

C.  

Enable the active STP port state on the bound Ethernet interface

D.  

Set the bound Ethernet trunk interface to non-FCoE native VLAN

Discussion 0
Question # 9

Question # 9

Question # 9

Refer to the exhibit. UCS- 1 fails to connect to the storage array. Which action resolves the issue?

Options:

A.  

Set the FI-A mode to FC End Host mode.

B.  

Enable N9K-1 mode to N-Port ID Virtualization.

C.  

Configure N-Port ID Virtualization on FI-

A.  

D.  

Implement N-Port Virtualization on N9K-1.

Discussion 0
Question # 10

A user reports that they cannot reach from a UCS server to an FC Storage array. Which command is used to test communication between an FCF and a target?

Options:

A.  

fcroute

B.  

traceroute

C.  

fcping

D.  

ping

Discussion 0
Get 300-615 dumps and pass your exam in 24 hours!

Free Exams Sample Questions