Pre-Summer Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65pass65

350-601 Implementing Cisco Data Center Core Technologies (350-601 DCCOR) is now Stable and With Pass Result | Test Your Knowledge for Free

Exams4sure Dumps

350-601 Practice Questions

Implementing Cisco Data Center Core Technologies (350-601 DCCOR)

Last Update 2 days ago
Total Questions : 382

Dive into our fully updated and stable 350-601 practice test platform, featuring all the latest CCNP Data Center exam questions added this week. Our preparation tool is more than just a Cisco study aid; it's a strategic advantage.

Our free CCNP Data Center practice questions crafted to reflect the domains and difficulty of the actual exam. The detailed rationales explain the 'why' behind each answer, reinforcing key concepts about 350-601. Use this test to pinpoint which areas you need to focus your study on.

350-601 PDF

350-601 PDF (Printable)
$54.25
$154.99

350-601 Testing Engine

350-601 PDF (Printable)
$59.5
$169.99

350-601 PDF + Testing Engine

350-601 PDF (Printable)
$74.55
$212.99
Question # 31

Drag and drop the mechanisms to collect data from a network from the left onto their characteristics on the right.

Question # 31

Options:

Discussion 0
Question # 32

Question # 32

Refer to the exhibit. A network engineer is using tcpdump to capture a

snapshot of OSPF-related traffic on a specific Cisco NX-OS switch port. For security reasons, the capture must be taken using an embedded container that is already deployed on the Cisco Nexus device. Which command completes the script?

Options:

A.  

Guestshell

B.  

Guestshell-bash

C.  

Run guestshell

D.  

Run bash

Discussion 0
Question # 33

Question # 33

Refer to the exhibit A Cisco VXLAN fabric must detect when a VM with an IP address of 11.0.0.100 moves between servers The engineer must also unfreeze the endpoint Which command accomplishes this goal?

Options:

A.  

delete ip arp 11.0.0.100 vrf Teat_Teko force-clear

B.  

clear ip arp 11.0.0 100 vrf Teat Telco force-delete

C.  

delete ip arp 11.0 0.100 vrf Teat Talco force-delete

D.  

clear ip arp 11.0 0 100 Teat Telco force-clear

Discussion 0
Question # 34

Which command must be run before downgrading a Cisco Nexus 9300 Series Switch?

Question # 34

Options:

A.  

Option A

B.  

Option B

C.  

Option C

D.  

Option D

Discussion 0
Question # 35

What is a characteristic of the NFS protocol?

Options:

A.  

It is used for booting Cisco UCS B-Series servers.

B.  

It is used to access a storage array at a block level.

C.  

It uses UDP and HTTP as its transport.

D.  

It uses remote procedure calls with TCP/IP for transport.

Discussion 0
Question # 36

Which two Cisco UCS components are upgraded when using Install Infrastructure Firmware? (Choose two.)

Options:

A.  

Cisco UCS Manager

B.  

board controller

C.  

I/O modules

D.  

storage adapters

E.  

BIOS

Discussion 0
Question # 37

Question # 37

Refer to the exhibit. What is the outcome of this command when the EPLD is updated on a Cisco Nexus 9000 Series Switch?

Options:

A.  

displays the impact of the upgrade on the operation of the switch

B.  

shows a simulated upgrade of the EPLD

C.  

displays the compatibility of the EPLD upgrade and the image in the bootflash

D.  

upgrades the EPLD on the switch disruptively

Discussion 0
Question # 38

Question # 38

Refer to the exhibit. In a Cisco ACI fabric, the status of interface Eth1/1 changes frequently. Which set of actions configures the fabric to disable Eth1/1 when the port flaps more than 10 times within 1 minute?

Options:

A.  

From fabric policies, set the time allowed for max flaps to 60.

B.  

From fabric policies set link debounce interval to 60.

C.  

From access policies, set the time allowed for max flaps to 60.

D.  

From access policies, set link debounce interval to 1.

Discussion 0
Question # 39

Drag and drop the items from the left into the corresponding columns as a feature or capability of inter sight Managed Mode or UCS Manager Mode.

Question # 39

Options:

Discussion 0
Question # 40

Question # 40

Refer to the exhibit An engineer must access a Cisco UCS C-Series server KVM from a remote location. The engineer must use the out-of-band interface to access the KVM Which configuration set meets these requirements?

Options:

A.  

NIC mode: Dedicated VLAN ID: 101

B.  

NIC mode: Shared LOM vlan state: Disabled

C.  

NIC mode Shared LOM VLAN ID 100

D.  

NIC mode Dedicated VLAN state Disabled

Discussion 0
Get 350-601 dumps and pass your exam in 24 hours!

Free Exams Sample Questions