3V0-23.25 Practice Questions
Advanced VMware Cloud Foundation 9.0 Storage
Last Update 1 day ago
Total Questions : 77
Dive into our fully updated and stable 3V0-23.25 practice test platform, featuring all the latest VCAP-Storage exam questions added this week. Our preparation tool is more than just a VMware study aid; it's a strategic advantage.
Our free VCAP-Storage practice questions crafted to reflect the domains and difficulty of the actual exam. The detailed rationales explain the 'why' behind each answer, reinforcing key concepts about 3V0-23.25. Use this test to pinpoint which areas you need to focus your study on.
A customer attaches an external Fibre Channel (FC) VMFS datastore to a VMware Cloud Foundation (VCF) workload domain for backup staging. The administrator must confirm that the datastore is visible to all hosts, and that path and device health alarms will trigger should a fabric link or path fail.
Which action should the administrator take to verify this?
A multinational corporation is deploying a VMware Cloud Foundation (VCF) Workload Domain cluster to host tier-1 business applications with the following requirements:
• Deliver high performance to all workloads.
• Integration with automated VM placement.
• Reuse of existing infrastructure including multiple Fibre Channel (FC) arrays partitioned by business unit.
• The storage architecture must avoid vSAN.
• Meet organizational separation requirements.
Which two deployment approaches meet these requirements? (Choose two.)
An administrator has been tasked with providing additional storage to an existing VMware Cloud Foundation (VCF) instance. The administrator decides to configure cross-cluster capacity sharing so that multiple independent vSAN HCI Clusters can consume storage of adjacent vSAN storage resources within the same workload domain.
What is a requirement of cross-cluster capacity sharing?
An administrator has deployed a three-host vSphere cluster with a small amount of VMFS storage and wants to add additional capacity from a vSAN ESA cluster located in the same vCenter Server.
When the administrator selects the vSphere cluster and navigates to the Configure tab, the Datastore Management option is missing under the vSAN section.
What prerequisite must be met before the administrator can mount the remote datastore?
A storage architect has been called into a meeting with the accounting team who is trying to determine why 20% of their raw capacity is not available for consumption. Their vSAN cluster was created with the following characteristics:
• 2 x 2 TB NVMe disks in 6 hosts in their vSAN cluster.
• FTT=1, RAID-1 for the default policy.
• Host Rebuild Reserve not activated for this cluster.
Which two items should the Architect say accounts for most of the unusable capacity? (Choose two.)
An administrator is tasked with vertically scaling a vSAN ESA deployment. The current cluster contains 6 hosts each with the following configuration:
• 8 x 7.68 TB drives
• 2 x 25 GB NICs
• 2 x Intel Gold CPUs
What are the three reasons to add the same model and capacity drives when scaling each host? (Choose three.)
An administrator is tasked with stretching a vSAN cluster in a VMware Cloud Foundation (VCF) Workload Domain across two availability zones within a region. Both availability zones contain an equal number of hosts.
What four Conditions must also be met in order to stretch the cluster?
Drag and drop the four correct options from the Options list on the left and place them into the Conditions on the right in any order. (Choose four.)

An architect has been tasked with designing a vSAN OSA storage solution for a VMware Cloud Foundation (VCF) Private Cloud. The following requirements and constraints have been gathered from the client:
• 2 x 4 TB NVMe disks per host
• 6 hosts
• FTT=1/RAID-5 for all deployed Virtual Machines
• Expected Dedupe/Compression Ratio = 2 (100%)
• Reserve enough capacity to rebuild a host completely in case of a failure (Host Rebuild Reservation)
• Operational Reserve of 10%
• Expected Overhead for Filesystem, Object, etc. of 25%
What is the approximate expected usable capacity of the resulting array?
An architect is presented with the following requirements for the storage solution in a VMware Cloud Foundation (VCF) Workload Domain.
The solution must:
• Allow for rapid recovery in case of an availability zone failure.
• Provide an extremely high amount of IOPS to all applications.
• Allow for additional storage to be added as application needs grow.
• Provide the lowest latency possible for configured applications.
• Provide recovery in case of datastore failure.
• Encrypt data in transit and at rest.
What two vSAN advanced technologies must be deployed to meet these requirements? (Choose two.)
An administrator is tasked designing a vSAN storage solution while respecting the following requirements:
• Must use vSAN ESA
• Must be stretched between two data centers
• Must configure Failures to tolerate = 1
• Must configure Erasure Coding
How many components per Virtual Machine (VM) will be created?