Month End Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: merry71

93-Tall-Mass-Timber-Buildings 93-Tall-Mass-Timber-Buildings is now Stable and With Pass Result | Test Your Knowledge for Free

Exams4sure Dumps

93-Tall-Mass-Timber-Buildings Practice Questions

93-Tall-Mass-Timber-Buildings

Last Update 1 day ago
Total Questions : 80

Dive into our fully updated and stable 93-Tall-Mass-Timber-Buildings practice test platform, featuring all the latest Special Inspector exam questions added this week. Our preparation tool is more than just a International Code Council study aid; it's a strategic advantage.

Our free Special Inspector practice questions crafted to reflect the domains and difficulty of the actual exam. The detailed rationales explain the 'why' behind each answer, reinforcing key concepts about 93-Tall-Mass-Timber-Buildings. Use this test to pinpoint which areas you need to focus your study on.

93-Tall-Mass-Timber-Buildings PDF

93-Tall-Mass-Timber-Buildings PDF (Printable)
$46.5
$154.99

93-Tall-Mass-Timber-Buildings Testing Engine

93-Tall-Mass-Timber-Buildings PDF (Printable)
$51
$169.99

93-Tall-Mass-Timber-Buildings PDF + Testing Engine

93-Tall-Mass-Timber-Buildings PDF (Printable)
$63.9
$212.99
Question # 1

Concealed spaces in a Type IV-C building must be protected with:

Options:

A.  

sprinklers per NFPA 13.

B.  

a lining of fire-retardant-treated wood.

C.  

the same protection as used for interior spaces in a Type IV-

C.  

D.  

noncombustible materials with at least 40 minutes of assigned protection time.

Discussion 0
Question # 2

In Type IV-C construction, a connection between two members of the primary structural frame supporting a floor is required to be protected to achieve a minimum fire-resistance rating of:

Options:

A.  

1 hour

B.  

1-1/2 hours

C.  

2 hours

D.  

3 hours

Discussion 0
Question # 3

Which of the following is true regarding Type IV-B unprotected portions of mass timber ceilings and walls?

Options:

A.  

All of the mass timber may be exposed.

B.  

None of the mass timber may be exposed.

C.  

20% of the floor area of the ceilings and 40% of the floor area of the walls may be exposed under certain conditions.

D.  

40% of the floor area of the ceilings and 20% of the floor area of the walls may be exposed under certain conditions.

Discussion 0
Question # 4

In mass timber construction of Type IV-C, the fire-resistance ratings of bearing walls are permitted to be reduced by _____ where supporting a roof only.

Options:

A.  

30-minutes

B.  

45-minutes

C.  

1-hour

D.  

2-hours

Discussion 0
Question # 5

Refer to the figure by clicking on the EXHIBIT button above.

Question # 5

Question # 5

In Type IV-B construction, unprotected portions of mass timber as shown in the Figure is limited to an area equal to not more than what percentage of the base floor area?

Options:

A.  

15%

B.  

20%

C.  

30%

D.  

40%

Discussion 0
Question # 6

The time, in minutes, contributed to the fire resistance rating by the noncombustible protection of mass timber building elements, components, or assemblies, shall be established through a comparison of assemblies tested using procedures set forth in ASTM Standard:

Options:

A.  

E114

B.  

E119

C.  

E920

D.  

D3498

Discussion 0
Question # 7

Which of the following is an acceptable alternative for protecting structural connections from fire in Type IV-A, IV-B or IV-C construction?

Options:

A.  

Testing of connections in accordance with ASTM E136

B.  

Limiting connections to those incorporating wood-on-wood bearing

C.  

Using connectors that are rated by the manufacturer for fire performance

D.  

Engineering analysis showing limited temperature rise at the connector for the required fire-resistance time of connected members

Discussion 0
Question # 8

In mass timber construction of Type IV-C, the fire-resistance ratings of bearing walls are permitted to be reduced by _____ where supporting a roof only.

Options:

A.  

30-minutes

B.  

45-minutes

C.  

1-hour

D.  

2-hours

Discussion 0
Question # 9

Which of the following is true regarding fire-resistance rating protection provided by noncombustible covering material?

Options:

A.  

1/2 in. gypsum board provides 30 minutes

B.  

1/2 in. Type X gypsum board provides 40 minutes

C.  

5/8 in. gypsum board provides 40 minutes

D.  

5/8 in. Type X gypsum board provides 40 minutes

Discussion 0
Question # 10

What fire-resistance rating is required for floors in Type IV-A, IV-B and IV-C construction?

Options:

A.  

1 hour

B.  

2 hours

C.  

3 hours

D.  

4 hours

Discussion 0