Cyber Monday Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65pass65

D-PST-MN-A-24 Dell PowerStore Maintenance Achievement is now Stable and With Pass Result | Test Your Knowledge for Free

D-PST-MN-A-24 Practice Questions

Dell PowerStore Maintenance Achievement

Last Update 3 days ago
Total Questions : 61

Dive into our fully updated and stable D-PST-MN-A-24 practice test platform, featuring all the latest Storage Administrator exam questions added this week. Our preparation tool is more than just a EMC study aid; it's a strategic advantage.

Our Storage Administrator practice questions crafted to reflect the domains and difficulty of the actual exam. The detailed rationales explain the 'why' behind each answer, reinforcing key concepts about D-PST-MN-A-24. Use this test to pinpoint which areas you need to focus your study on.

D-PST-MN-A-24 PDF

D-PST-MN-A-24 PDF (Printable)
$43.75
$124.99

D-PST-MN-A-24 Testing Engine

D-PST-MN-A-24 PDF (Printable)
$50.75
$144.99

D-PST-MN-A-24 PDF + Testing Engine

D-PST-MN-A-24 PDF (Printable)
$63.7
$181.99
Question # 1

A Storage Administrator needs to add drives to a base enclosure of a Dell EMC PowerStore 3000X system. The system currently contains 10 750-GB NVMe SCM drives.Which

drive configuration maximizes the base enclosure capacity?

Options:

A.  

13 750-GB NVMe SCM drives in slots 10-22

B.  

11 750-GB NVMe SCM drives in slots 10-20

C.  

13 15360-GB NVMe SSD drives in slots 10-22

D.  

11 15360-GB NVMe SSD drives in slots 10-20

Discussion 0
Question # 2

What is an alternative way to collect logs instead of using the Dell EMC PowerStore manager GUI?

Options:

A.  

Data Collect using Service Container

B.  

USB stick inserted into the system

C.  

Data Collect using vCenter

D.  

Discovery Utility

Discussion 0
Question # 3

Question # 3

Refer to the exhibit.

What is indicated when the circled LED on an expansion enclosure is illuminated amber?

Options:

A.  

Expansion enclosure power-on

B.  

Expansion enclosure faulted

C.  

SAS bus link down

D.  

SAS bus link up

Discussion 0
Question # 4

While on-site installing a Dell EMC PowerStore system, the node A and B embedded module fault LEDs are alternating blue and amber (blue for 3 seconds). What does this

indicate?

Options:

A.  

Nodes are in service mode

B.  

Nodes are in degraded mode

C.  

The system is not initialized

D.  

The system is booting

Discussion 0
Question # 5

When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?

Options:

A.  

svc_node restart

svc_rescue_state start

B.  

svc_node shutdown

svc_rescue_state clear

C.  

svc_rescue_state clear

svc_node reboot

D.  

svc_rescue_state normal

svc_node start

Discussion 0
Question # 6

In which step of the ICW can the configuration details be exported?

Options:

A.  

Support Assist

B.  

Cluster Configuration

C.  

Cluster Details

Discussion 0
Question # 7

While on-site troubleshooting a Dell EMC PowerStore system, the node B embedded module fault LED is blinking blue and amber alternating at one second intervals. What doesthis indicate?

Options:

A.  

Node is in service mode

B.  

System is not initialized

C.  

Node is booting

D.  

Node is in degraded mode

Discussion 0
Question # 8

A Storage Administrator notices a Critical alert present in Dell EMC PowerStore Manager relating to data integrity. What action within the alert details slide-out panel is helpful in

troubleshooting the problem?

Options:

A.  

Examine Notifications to obtain a list of corrective actions

B.  

Access the Repair Flow link to schedule a support engagement

C.  

Re-engage support through previous listed Related Events

D.  

Select the Gather Support Materials from Service and Support

Discussion 0
Question # 9

Through which network do external hosts connect to the cluster for data access?

Options:

A.  

Storage

B.  

Management

C.  

Service

D.  

Internal

Discussion 0
Question # 10

What is the result of setting a VLAN ID of 0 on a network when running ICW for Dell EMC PowerStore?

Options:

A.  

Default route is set

B.  

Network will pass tagged traffic

C.  

Network will pass untagged traffic

D.  

Static route is set

Discussion 0
Get D-PST-MN-A-24 dumps and pass your exam in 24 hours!

Free Exams Sample Questions