Free Dell VPLEX Operate Achievement Practice Questions

Question # 1

At which stage of configuring a virtual volume on VPLEX is the RAID level defined?

Options:

A.  

Claimed volume

B.  

Extent

C.  

Device

D.  

Storage volume

Discussion 0
Question # 2

What determines which cluster will service I/O in the event of a WAN COM failure for a distributed device that is not a member of a consistency group?

Options:

A.  

Detach rule of the storage view

B.  

Rule set of the distributed device

C.  

Detach rule of the consistency group

D.  

VPLEX Witness

Discussion 0
Question # 3

Which command is used to display available statistics for monitoring VPLEX?

Options:

A.  

monitor create

B.  

monitor collect

C.  

monitor stat-list

D.  

monitor add-sink

Discussion 0
Question # 4

What condition would prevent volume expansion?

Options:

A.  

Migration occurring on the volume

B.  

Volume not belonging to a consistency group

C.  

Metadata volume being backed up

D.  

Logging volume in re-synchronization state

Discussion 0
Question # 5

What are the two common use cases of the VPLEX Mobility feature?

Options:

A.  

Tech Refresh

Workload Rebalance

B.  

Workflow Automation

Tech Refresh

C.  

NDU upgrades

Continuous Data Protection

D.  

Workload Rebalance

Deduplication

Discussion 0
Question # 6

What are characteristics of a storage view?

Options:

A.  

An initiator can only be in multiple storage view

VPLEX FE port can be in multiple storage views

Each initiator and FE port pair must be in different storage views

B.  

An initiator can be in multiple storage views

VPLEX FE port can be in multiple storage views

Each initiator and FE port pair can only be in one storage view

C.  

An initiator can only be in one storage view

VPLEX FE port can be in multiple storage views

Each initiator and FE port pair can be in different storage views

D.  

An initiator can be in multiple storage views

VPLEX FE port can only be in one storage view

Each initiator and FE port pair can only be in one storage view

Discussion 0
Question # 7

How can a VPLEX storage administrator manage array-based attributes?

Options:

A.  

Volume tiers

B.  

Extent tiers

C.  

Device tiers

D.  

Storage tiers

Discussion 0
Question # 8

A service provider has implemented a VPLEX Metro cluster without VPLEX Witness and has implemented a static rule set. The static rule set has been set to "cluster-2

detaches". A Microsoft Windows host in the Cluster-1 data center uses a distributed volume. However, the WAN COM fails.

What is the result of this failure?

Options:

A.  

1. VPLEX suspends I/O to all distributed devices on both clusters

2. VPLEX starts a delay timer

3. If connectivity is not restored within the timer expiration period, VPLEX resumes I/O on Cluster-1 and keeps I/O suspended on Cluster-2

B.  

1. VPLEX starts a delay timer

2. VPLEX suspends I/O to all distributed devices on both clusters

3. If connectivity is not restored within the timer expiration period, VPLEX resumes I/O on Cluster-2 and keeps I/O suspended on Cluster-1

C.  

1. VPLEX suspends I/O to all distributed devices on both clusters

2. VPLEX starts a delay timer

3. If connectivity is not restored within the timer expiration period, VPLEX resumes I/O on Cluster-2 and keep I/O suspended on Cluster-1

D.  

1. VPLEX starts a delay timer

2. VPLEX suspends I/O to all distributed devices on both clusters

3. If connectivity is not restored within the timer expiration period, VPLEX resumes I/O on Cluster-1 and keeps I/O suspended on Cluster-2

Discussion 0
Question # 9

A storage administrator has been tasked with migrating a Microsoft SQL Server and its native EMC VNX LUNs behind a VPLEX Local cluster. However, in planning for future

application growth, the database administrator wants to be able to expand the storage volumes.

Based on this information, which geometry should be selected during encapsulation?

Options:

A.  

RAID-0

B.  

RAID-C

C.  

1:1 Mapping

D.  

Stripped MetaLUN

Discussion 0
Question # 10

Question # 10

Refer to the exhibit.

Which displayed storage volume is available to be used for the creation of an extent?

Options:

A.  

2

B.  

1

C.  

4

D.  

3

Discussion 0

D-VPX-OE-A-24 PDF

D-VPX-OE-A-24 PDF (Printable)
$46.5
$154.99

D-VPX-OE-A-24 Testing Engine

D-VPX-OE-A-24 PDF (Printable)
$51
$169.99

D-VPX-OE-A-24 PDF + Testing Engine

D-VPX-OE-A-24 PDF (Printable)
$63.9
$212.99
Exams4sure Dumps

Exam style questions across every D-VPX-OE-A-24 domain

Last Update 3 days ago
Total Questions : 60

Start with our free D-VPX-OE-A-24 practice questions, carefully crafted to mirror the domains, phrasing, and difficulty of the real Storage Administrator exam. Each D-VPX-OE-A-24 exam question comes with a detailed rationale that explains not just which answer is correct but why the others fall short. That's how concepts stick. Use the free set to benchmark yourself: identify your DELL EMC weak domains, see where you're losing marks, and build a focused study plan in minutes.

Free Exams Sample Questions