Question # 21

The UPS5000-A parallel signal cable does not adoptring connection, which reducessystem reliability because of the possibility of single-point failures.

Options:

A.  

TRUE

B.  

FALSE

Discussion 0
Question # 22

How many batteries does the UPS2000-G series (15 kVA to 20 kVA) support? () (Multiple Choice)

Options:

A.  

28

B.  

32

C.  

36

D.  

40

Discussion 0
Question # 23

Which of the following are the features of the PDU for the UPS2000-G series (6 kVA to 20 kVA)? (Multiple Choice)

Options:

A.  

The PDU implements input/output power distribution for two UPSs in parallel.

B.  

The PDU provides a central maintenance bypass for a stand-alone system or parallel systems.

C.  

The PDU uses an extension output socket with the following specifications: OT; 4 x C13; 2 x C19.

D.  

The PDU monitors the surrounding environment and generates an alarm when an error occurs.

Discussion 0
Question # 24

The standard number of batteries in a single battery pack for the UPS2000-G series (6 kVA to 20 kVA) is ().

Options:

A.  

16

B.  

17

C.  

18

D.  

20

Discussion 0
Question # 25

The UPS5000-A 30-120 kVA can be wall-mounted.

Options:

A.  

TRUE

B.  

FALSE

Discussion 0
Question # 26

What is the maximum capacity of the UPS5000-E power module?

Options:

A.  

20 kVA

B.  

30 kVA

C.  

40 kVA

D.  

50 kVA

Discussion 0
Question # 27

The highest temperature in the local area is () when selects T3 air conditioning?

Options:

A.  

30-35°C

B.  

35-43°C

C.  

43-55°C

D.  

55-65°C

Discussion 0
Question # 28

Which of the following functions can a modular UPS realize? (Multiple Choice)

Options:

A.  

Online expansion

B.  

Online hot swap

C.  

2N redundancy configuration for a single UPS

D.  

N+X redundancy configuration for a single UPS

Discussion 0
Question # 29

The THDV of the UPS5000-A at full linear loads is ().

Options:

A.  

0.01

B.  

0.02

C.  

0.03

D.  

0.05

Discussion 0
Question # 30

Which of the following statements is correct about the UPS5000-S at lowloads? (Multiple Choice)

Options:

A.  

The system efficiency is 95% at 20% loads.

B.  

The system efficiency is 96.5% at 20% loads.

C.  

The system efficiency is 96% at 40% loads.

D.  

The system efficiency is 97% at 40% loads.

Discussion 0