E20-260 is stable now with all latest exam questions are added 3 days ago. Just download our Full package and start your journey with EMC VPLEX Specialist Exam for Implementation Engineers certification. All these EMC E20-260 practice exam questions are real and verified by our Experts in the related industry fields.

E20-260 PDF

E20-260 PDF (Printable)
$48
$119.99

E20-260 Testing Engine

E20-260 PDF (Printable)
$56
$139.99

E20-260 PDF + Testing Engine

E20-260 PDF (Printable)
$70.8
$176.99
Question # 1

A customer has a VPLEX Metro/GEO environment and is requesting that the VPLEX Witness be installed.

The requirements for the Witness are:

  • One vCPU
  • 512MB ram
  • 2.5GB storage space

What platform type is supported?

Options:

A.  

64bit ESX4.0 and above

B.  

32/64bit ESXi 5.0

C.  

64bit MS Hyper-V 2012

D.  

VMware Workstation 9.0 and above

Discussion 0
Question # 2

In a customer's VPLEX Metro environment, a host has been provisioned as a single virtual volume from cluster-1. The customer now needs to convert the local virtual volume to a distributed device.

How can the customer accomplish this?

Options:

A.  

Add an unused virtual volume from cluster-2 as a remote mirror to the virtual volume on cluster-1

B.  

Add an unused device from cluster-2 as a remote mirror to the virtual volume on cluster-1

C.  

Enable remote access to an unused virtual volume from cluster-2 and add it as a remote mirror.

D.  

Enable remote access to an unused device from cluster-2 and add it as a remote mirror.

Discussion 0
Question # 3

Refer to the exhibit.

Question # 3

A customer is requesting a performance analysis for their distributed volumes in a Metro configuration to ensure there are no issues with a recent implementation.

What additional files should be collected?

Options:

A.  

Perpetual log files from Cluster-2

B.  

firmware.log from Cluster-1

C.  

Health-Check output from Cluster-2

D.  

VPLEX Performance GUI export from both clusters

Discussion 0
Question # 4

How does VPLEX access back-end arrays?

Options:

A.  

Through Virtual Targets

B.  

Through Virtual Initiators

C.  

Through the front-end ports on the Management station

D.  

VPLEX provides storage through its own DAE(s)

Discussion 0
Question # 5

What is a group of VPLEX directors that participate in the cache coherence protocol for a virtual volume?

Options:

A.  

Share Group

B.  

Consistency Group

C.  

Storage View

D.  

Administrative Domain

Discussion 0
Question # 6

A VPLEX administrator claims a 100GB Storage Volume that is thin provisioned on the storage array and has 25GB physically allocated and creates a 1:1 encapsulated virtual volume. After a local data mobility job for that Virtual Volume, the storage array administrator notices that the allocated capacity has increased to 100G

B.  

Why did this happen?

Options:

A.  

The destination Storage Volume was not claimed with the thin-rebuild parameter in VPLEX.

B.  

VPLEX does not support thin devices.

C.  

Neither the source nor the destination Storage Volume were claimed with the thin-rebuild parameter in VPLEX.

D.  

The source Storage Volume was not claimed with the thin-rebuild parameter in VPLEX.

Discussion 0
Question # 7

A customer has just introduced a new VPLEX cluster into their storage environment with numerous existing storage arrays. They need to present the host's existing data from the VPLEX cluster.

Which method would you use to perform this operation?

Options:

A.  

Distribute

B.  

Stripe

C.  

Concatenate

D.  

Encapsulate

Discussion 0
Question # 8

Refer to the exhibit.

Question # 8

Which two metavolume candidates should be used to complete the displayed command?

Options:

A.  

1 and 2

B.  

5 and 6

C.  

1 and 3

D.  

3 and 4

Discussion 0
Question # 9

Refer to the exhibit.

Question # 9

Which VPLEX configuration is shown?

Options:

A.  

VPLEX Metro/GEO dual engine

B.  

VPLEX Local quad engine

C.  

VPLEX Metro/GEO quad engine

D.  

VPLEX Local dual engine

Discussion 0
Question # 10

What is required of an ESX host for the Witness to be installed?

Options:

A.  

MAC address change set to Accept

B.  

Promiscuous mode set to Accept

C.  

ESX host in Cluster 1 failure domain

D.  

ESX host in Cluster 2 failure domain

Discussion 0
Question # 11

A customer is performing maintenance on their network that might affect their VPLEX Witness VM.

What can be done to ensure there are no adverse effects due to a Witness outage?

Options:

A.  

Disable the cluster's management server ipsec.

B.  

Disable the VPLEX Witness.

C.  

Shut down the VPLEX Witness VM.

D.  

Shut down the cluster's management server.

Discussion 0
Question # 12

Which is a best practice recommended for VPLEX Metro inter-cluster WAN settings?

Options:

A.  

Allow auto-negotiation to select the optimal transmission rate

B.  

Always use the defaults

C.  

Always set the MTU to 9000

D.  

Tune the network parameters according to the specifics of the configuration

Discussion 0
Question # 13

A dual fan failure occurs on a single VPLEX engine.

What will be the result?

Options:

A.  

The engine will shut down immediately.

B.  

Director B only will shut down.

C.  

Director A only will shut down.

D.  

The engine will shut down after three minutes.

Discussion 0
Question # 14

A customer has a database application that has multiple distributed virtual volumes. They want to ensure that in the event that one of their data centers goes offline, the virtual volumes will all be available to the surviving site.

What VPLEX option should they implement?

Options:

A.  

Data Mobility

B.  

Consistency Groups

C.  

Distributed Device

D.  

Remote Access

Discussion 0
Question # 15

Which is a best practice recommended for VPLEX Metro inter-cluster WAN settings?

Options:

A.  

Always use the defaults

B.  

Allow auto-negotiation to select the optimal transmission rate

C.  

Always set the MTU to 9000

D.  

Tune the network parameters according to the specifics of the configuration

Discussion 0
Question # 16

Refer to the exhibit.

Question # 16

You are preparing to upgrade a VPLEX Metro system. You ran the version command to begin the verification process and received the output shown.

What is the most likely reason for the warning?

Options:

A.  

The Metadata volume is in an NDU state.

B.  

The Cluster Witness is at the wrong version.

C.  

The Management Server is at the wrong version.

D.  

The directors are in an NDU state.

Discussion 0
Question # 17

What are the three components that a drill-down command can be run against to provide a more detailed analysis?

Options:

A.  

Storage-View, Virtual-Volume, Device

B.  

Storage-View, Virtual-Volume, Storage-Volume

C.  

Storage-View, Consistency-Group, Device

D.  

Storage-View, Virtual-Volume, Extent

Discussion 0
Question # 18

Which element does VPLEX Witness require?

Options:

A.  

Virtual Volume

B.  

Distributed Volume

C.  

Distributed Device

D.  

Consistency Group

Discussion 0
Question # 19

Refer to the exhibit.

Question # 19

You are planning to perform data mobility between VPLEX Clusters using the GUI. What mobility job options do you have?

Options:

A.  

create, stop, activate, monitor, pause, throttle and terminate

B.  

create, activate, fracture, resync, monitor, pause, and commit

C.  

create, cancel, suspend, monitor, pause, throttle, and terminate

D.  

create, remove, cancel, monitor, pause, throttle, and commit

Discussion 0
Question # 20

Which three elements are part of the VPLEX Storage View?

Options:

A.  

VPLEX FE Port, Initiator, Virtual Volume

B.  

VPLEX FE Port, Top-Level Device, Storage Volume

C.  

VPLEX BE Port,VPLEX FE Port, Virtual Volume

D.  

VPLEX BE Port, Initiator, Virtual Volume

Discussion 0
Question # 21

In a VPLEX Metro with Witness, which command checks the status and uptime of VPN, and returns the remote VPLEX management IP address and the witness public IP address?

Options:

A.  

shell command sudo /usr/sbin/ipsec statusall

B.  

vplexcli command cluster status

C.  

shell command /sbin/ifconfig

D.  

vplexcli command VPlexadmin show

Discussion 0
Question # 22

A customer has a quad-engine VPLEX Metro configuration and has stated they want to review their performance metrics from the past 4 hrs on the entire cluster. How many performing log files will they need to pull from the management server in order to analyze all of their components?

Options:

A.  

16 performance log files

B.  

8 performance log files

C.  

2 performance log files

D.  

None, all metrics are displayed in the Unisphere GUI

Discussion 0
Question # 23

A customer wants to collect performance data for specific virtual-volumes and has created the performance monitor.

What step needs to be performed to enable data capture?

Options:

A.  

The customer needs to utilize the "-capture" flag when creating the monitor

B.  

Virtual-volumes cannot have any performance data collected against them

C.  

The customer needs to create an associated sink for data collection

D.  

The customer needs to enable performance collection through the VPLEX GUI

Discussion 0
Question # 24

Which type of statistics are used to track latencies, determine median, mode, percentiles, minimums and maximums?

Options:

A.  

Buckets

B.  

Counters

C.  

Readings

D.  

Monitors

Discussion 0
Question # 25

You are preparing to migrate the topology of an installed VPLEX Local system. What is a supported upgrade path?

Options:

A.  

Local to Geo to Global

B.  

Local to Metro

C.  

Local to Global

D.  

Local to Metro to Geo

Discussion 0
Question # 26

Refer to the exhibit.

Question # 26

For what is the module labeled "E" used?

Options:

A.  

Director A Front-end Connectivity

B.  

Director A Back-end Connectivity

C.  

Director A WAN COM Connectivity

D.  

Director A Local Com Connectivity

Discussion 0
Question # 27

Refer to the exhibit.

Question # 27

After the "attach-mirror" command is successfully executed on device "device_VNX0506_CSE__6_1", the command "rebuild-status" shows an ongoing rebuild process on the same device.

What is a possible cause?

Options:

A.  

It is a normal behavior. when attaching a mirror, a rebuild process starts.

B.  

The device "device_VNX0506_CSE__6_1" has an ongoing rebuild process for a previous failure.

C.  

The rebuild process is related to a director failure.

D.  

The device mirror will start only after the rebuild process is completed.

Discussion 0
Question # 28

You are using VPLEX Unisphere to perform management functions in your environment. You are tasked with creating several volume migrations to a new storage array.

What tab should you use to perform this migration?

Options:

A.  

Provision Storage

B.  

Mobility Central

C.  

System Status

D.  

Performance Dashboard

Discussion 0
Question # 29

Which type of statistics is used to track latencies, determine median, mode, percentiles, minimums and maximums?

Options:

A.  

Counters

B.  

Readings

C.  

Buckets

D.  

Monitors

Discussion 0
Question # 30

Refer to the exhibit.

Question # 30

You have created a Distributed Device in a VPLEX Metro. You want to confirm you have chosen the correct volumes before performing a mobility job across clusters. You will be moving the device to cluster 1.

Which object will be the source for this operation?

Options:

A.  

extent_Symm0841_03A7_1

B.  

DD_8_32012Nov26_183659

C.  

Symm0841_03A7

D.  

DD_7_3

Discussion 0
Question # 31

Refer to the exhibit.

Question # 31

During a short power disruption to cluster 2, director-2-1-A had failed. Power was restored after 5 minutes. In examining the output of the vault status command, you note that cluster-2's status reads "Cluster is not vaulting/unvaulting".

Why did this message appear?

Options:

A.  

There was no power disruption at cluster-1

B.  

The power disruption affected a single director only.

C.  

The power disruption did not affect all "A" directors.

D.  

The vaulting process runs on cluster-1

Discussion 0
Get E20-260 dumps and pass your exam in 24 hours!

Free Exams Sample Questions