Labour Day Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 2493360325

Good News !!! NS0-194 NetApp Certified Support Engineer (NCSE) is now Stable and With Pass Result

NS0-194 Practice Exam Questions and Answers

NetApp Certified Support Engineer (NCSE)

Last Update 1 day ago
Total Questions : 60

NS0-194 is stable now with all latest exam questions are added 1 day ago. Just download our Full package and start your journey with Netapp NetApp Certified Support Engineer (NCSE) certification. All these Netapp NS0-194 practice exam questions are real and verified by our Experts in the related industry fields.

NS0-194 PDF

NS0-194 PDF (Printable)
$48
$119.99

NS0-194 Testing Engine

NS0-194 PDF (Printable)
$56
$139.99

NS0-194 PDF + Testing Engine

NS0-194 PDF (Printable)
$70.8
$176.99
Question # 1

Your customer's MetroCluster has generated a "DISK REDUNDANCY FAILED" message.

Netapp-EmA:

Tue Jan 14 04:12:12 CET [netapp-EmA:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv' failed.

Tue Jan 14 04:12:13 CET [netapp-EmA:rv.connection.torndown:info]: HA interconnect: cfo_rv1 is torn down on NIC 1.

Tue Jan 14 04:12:13 CET [netapp-EmA:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'1 failed.

Tue Jan 14 04:12:15 CET [netapp-EmA:rv.connection.torndown:info]: HA interconnect: cfo_rv2 is torn down on NIC 1.

Tue Jan 14 04:12:18 CET [netapp-EmA:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'2 failed.

Tue Jan 14 04:12:19 CET [netapp-EmA:bridge.removed:info]: FC-to_SAS bridge siteB_2:13.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111161] was removed

Tue Jan 14 04:12:19 CET [netapp-EmA:bridge.removed:info]: FC-to_SAS bridge siteB_2:5.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111160] was removed

Netapp-EmB:

Tue Jan 14 04:12:12 CET [netapp-EmB:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv' failed.

Tue Jan 14 04:12:12 CET [netapp-EmB:rv.connection.torndown:info]: HA interconnect: cfo_rv2 is torn down on NIC 1.

Tue Jan 14 04:12:13 CET [netapp-EmB:rv.connection.torndown:info]: HA interconnect: cfo_rv1 is torn down on NIC 1.

Tue Jan 14 04:12:13 CET [netapp-EmB:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'1 failed.

Tue Jan 14 04:12:18 CET [netapp-EmB:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'2 failed.

Tue Jan 14 04:12:19 CET [netapp-EmB:bridge.removed:info]: FC-to_SAS bridge siteA_2:13.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111167] was removed

Tue Jan 14 04:12:19 CET [netapp-EmB:bridge.removed:info]: FC-to_SAS bridge siteA_2:5.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111164] was removed

Referring to the messages shown in the exhibit for each node, which component is causing the problem?

Options:

A.  

the ATTO bridge on siteB_2

B.  

the SAN switch siteA_2

C.  

the SAN switch siteB_2

D.  

the ISL between siteA and site B

Discussion 0
Question # 2

How many data-serving SVMs are supported with Cloud Volumes ONTAP that is running ONTAP 9.5?

Options:

A.  

128

B.  

1024

C.  

1

D.  

10

Discussion 0
Question # 3

You are working on a fabric MetroCluster. After a site failure, the plex starts to resync automatically to the aggregate mirror of Aggr1. The plex now shows a status of resyncing. During this process, you experience a slow resync of the SyncMirror plex.

In this scenario, how do you solve the problem?

Options:

A.  

Add more disks to the aggregate to add more I/O capacity.

B.  

Destroy and re-create plex, then run a baseline sync.

C.  

Tune the resync speed by adding a QoS policy and limit the concurrent I/O to the aggregate.

D.  

Tune the resync speed using the storage raid-options command.

Discussion 0
Question # 4

A disaster causes a FlexGroup volume to be unrecoverable, but it was protected by a SnapMirror relationship. You solve the issue, and the source is operational. Now, you want to return to serving the data from the original source.

In this scenario, what do you do next?

Options:

A.  

Initialize the SnapMirror relationship.

B.  

Restore data from a backup copy.

C.  

Perform a SnapMirror update.

D.  

Delete the SnapMirror relationship.

Discussion 0
Question # 5

Source Path Destination Path Relationship ID Relationship Type

msgld: msragld: 78e304e0-9781-1234-abcd-00a098d771bd XDP

msxpgld: msraxpgld: 3ca42ab4-9782-1234-abcd-00a098d771bd XDP

na_docavgld: ndradocavgld: a4b233b2-9783-1234-abcd-00a098d771bd XDP

na_dr: ndradr: c97d36a0-6d7c-11e8-83fb-00a098d771bd XDP

na_gld: ndragld: 9e7e034d-9782-1234-abcd-00a098d771bd XDP

na_mpgld: ndrampgld: 16e52e0d-9783-1234-abcd-00a098d771bd XDP

na_opengld: ndraopengld: dabb1813-9780-1234-abcd-00a098d771bd XDP

na_poc: ndrapoc: c1d632d7-977b-1234-abcd-00a098d771bd XDP

na_pubgld: ndrapubgld: 1a3f866c-9780-1234-abcd-00a098d771bd XDP

Referring to the output, which type of SnapMirror destination relationship is being used?

Options:

A.  

Single Volume SnapMirror Asynchronous

B.  

Single Volume SnapMirror Synchronous

C.  

SnapVault

D.  

Storage Virtual Machine DR

Discussion 0
Question # 6

Which two statements describe ONTAP NVRAM? (Choose two.)

Options:

A.  

ONTAP NVRAM is used as read cache.

B.  

ONTAP NVRAM stores uncommitted writes.

C.  

ONTAP NVRAM is used as write cache.

D.  

ONTAP NVRAM is battery backed.

Discussion 0
Question # 7

Referring to the exhibit, which two components should be examined? (Choose two.)

Question # 7

Options:

A.  

cluster switches

B.  

SAS adapter

C.  

network interface card

D.  

disk

Discussion 0
Question # 8

A customer must store physical hard copies of transaction data off site to meet regulatory requirements.

Which NetApp technology enables the customer to accomplish this task?

Options:

A.  

SnapVault

B.  

NDMP

C.  

SVM DR

D.  

FlexCache

Discussion 0
Question # 9

You have an ONTAP 2-node cluster. You run a read/write test workload against an SMB share, and it is slower than you expected. You run the same test again, but this time you monitor the storage using a QoS command.

Question # 9

Referring to the exhibit, what is the problem?

Options:

A.  

There is a disk bottleneck.

B.  

An HA interconnect problem is present.

C.  

The SMB read sizes should be increased.

D.  

The NVRAM needs to be replaced.

Discussion 0
Get NS0-194 dumps and pass your exam in 24 hours!

Free Exams Sample Questions