Labour Day Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 2493360325

Good News !!! RCDD-002 BICSI Registered Communications Distribution Designer - RCDD is now Stable and With Pass Result

RCDD-002 Practice Exam Questions and Answers

BICSI Registered Communications Distribution Designer - RCDD

Last Update 3 days ago
Total Questions : 361

BICSI Registered Communications Distribution Designer - RCDD is stable now with all latest exam questions are added 3 days ago. Incorporating RCDD-002 practice exam questions into your study plan is more than just a preparation strategy.

By familiarizing yourself with the BICSI Registered Communications Distribution Designer - RCDD exam format, identifying knowledge gaps, applying theoretical knowledge in BICSI practical scenarios, you are setting yourself up for success. RCDD-002 exam dumps provide a realistic preview, helping you to adapt your preparation strategy accordingly.

RCDD-002 exam questions often include scenarios and problem-solving exercises that mirror real-world challenges. Working through RCDD-002 dumps allows you to practice pacing yourself, ensuring that you can complete all BICSI Registered Communications Distribution Designer - RCDD exam questions within the allotted time frame without sacrificing accuracy.

RCDD-002 PDF

RCDD-002 PDF (Printable)
$48
$119.99

RCDD-002 Testing Engine

RCDD-002 PDF (Printable)
$56
$139.99

RCDD-002 PDF + Testing Engine

RCDD-002 PDF (Printable)
$70.8
$176.99
Question # 1

You are renovating telecommunication rooms that support an acute care facility that has 10,000 sq ft floors. The facility will be adding 15,000 sq ft to each of the floors. What is the MINIMUM additional floor space that you will need to expand the TRs to support the new floor space?

Options:

A.  

3 m x 3 m (10 ft x 10 ft)

B.  

3.5 m x 4.3 m (11.5 ft x 14 ft)

C.  

3.0 m x 4.5 m (10 ft x 15 ft)

D.  

6 m x 6 m (20 ft x 20 ft)

Discussion 0
Question # 2

You are designing an interactive patient television system (IPTS) that will provide internet, nurse call and LCD television services. From the following, which medium will NOT support these services in a backbone cabling system?

Options:

A.  

Balanced twisted pair

B.  

Coaxial 1/2 inch hard-line cable

C.  

Multimode optical fiber cable

D.  

RG-11 coaxial cable

Discussion 0
Question # 3

Which of the following is used to create an electronic signal that can be sent to the central nurse call equipment?

Options:

A.  

Headend module

B.  

Initiation device

C.  

Notification device

D.  

Two tone device

Discussion 0
Question # 4

What is the expected lumenance value, in watts, of a 200 watt fluorescent lamp after three years?

Options:

A.  

120 watts

B.  

140 watts

C.  

160 watts

D.  

180 watts

E.  

200 watts

Discussion 0
Question # 5

What is the expected life cycle, in years, of building automation system within a building structure with a life cycle of 40+ years?

Options:

A.  

1 to 2

B.  

2 to 4

C.  

5 to 7

D.  

8 to 12

E.  

12 to 15

Discussion 0
Question # 6

Within a commercial office building of 2300 sq m (25000 sq ft), how many building automation system (BAS) devices are required?

Options:

A.  

50

B.  

75

C.  

100

D.  

125

E.  

150

Discussion 0
Question # 7

Color codes for cross-connection fields have been used for many years. Which color is used to identify network connections?

Options:

A.  

Green

B.  

Orange

C.  

Purple

D.  

Yellow

E.  

Brown

Discussion 0
Question # 8

Color codes for cross-connections fields have been used for many years. Which color is used to identify campus backbone?

Options:

A.  

Brown

B.  

Blue

C.  

Green

D.  

Purple

E.  

White

Discussion 0
Question # 9

Color codes for cross-connections fields have been used for many years. Which color is used to identify horizontal cable?

Options:

A.  

Blue

B.  

Green

C.  

Purple

D.  

Orange

E.  

Brown

Discussion 0
Question # 10

Which of the following is a nonmechanical firestop system?

Options:

A.  

Cable transit system

B.  

Firestop blocks

C.  

Fire rated pathway device

D.  

Factory fabricated sleeve system

Discussion 0
Question # 11

A ________ eliminates the need to remove or install materials.

Options:

A.  

Cast-in-place device

B.  

Cable transit system

C.  

Fire-rated pathway device

D.  

Factory fabricated sleeve system

Discussion 0
Question # 12

Cementitious materials are ________ based materials.

Options:

A.  

Dry powder

B.  

Latex

C.  

Solvent

D.  

Sand

Discussion 0
Question # 13

The MAXIMUM span length for an aerial entrance, from the last pole to the building, must NOT exceed:

Options:

A.  

15.2 m (50 ft)

B.  

30 m (100 ft)

C.  

45.8 m (150 ft)

D.  

61 m (200 ft)

E.  

76 m (250 ft)

Discussion 0
Question # 14

Which one of the following is NOT an advantage of underground conduit?

Options:

A.  

Has a low initial installation cost

B.  

Preserves the aesthetic appearance of the premises

C.  

Adaptable for future placement or removal of facilities

D.  

Provides the security of additional physical cable protection

E.  

Is economical over a long life

Discussion 0
Question # 15

What is the horizontal separation, in well tamped earth, required between power and direct buried telecommunications facilities sharing the same trench?

Options:

A.  

152 mm (6 in)

B.  

229 mm (9 in)

C.  

300 mm (12 in)

D.  

381 mm (15 in)

E.  

457 mm (18 in)

Discussion 0
Question # 16

When balanced twisted-pair copper cabling, return loss is a measurement of the:

Options:

A.  

Worst case difference in magnitude between the expected insertion loss and the actual measured insertion loss

B.  

Reflection of signal power resulting from the insertion of a device in a transmission line (in dB)

C.  

Signal coupling between any two pairs along the entire length of the cabling

D.  

Loss in signal resulting from the insertion of a component, of link, or channel, between a transmitter and a receiver

E.  

Time required for a signal to travel from one end of the transmission path to the other end

Discussion 0
Question # 17

Where backbone cabling exceeds cabling lengths for the same performance or design (for product used in horizontal cabling), there are three fundamental tests which should be considered when testing. They are:

Options:

A.  

Insertion loss (attenuation), return loss, and wiremap/strand identification

B.  

Insertion loss (attenuation), return loss, and continuity

C.  

Insertion loss (attenuation), return loss, and length

D.  

Insertion loss (attenuation), continuity, and wiremap/strand identification

E.  

Continuity, wiremap/strand identification, and propagation delay/delay skew

Discussion 0
Question # 18

Premises optical fiber links should be tested:

Options:

A.  

In one direction at one corresponding wavelength

B.  

In one direction at both corresponding wavelengths

C.  

Bidirectionally at one corresponding wavelength

D.  

Bidirectionally at both corresponding wavelengths

Discussion 0
Question # 19

The MINIMUM dimensions of the telecommunications main grounding busbar is ________ and variable in length.

Options:

A.  

4 mm (0.16 in) x 80 mm (3.15 in)

B.  

6.3 mm (0.25 in) x 100 mm (4 in)

C.  

8 mm (0.31 in) x 110 mm (4.33 in)

D.  

10.5 mm (0.41 in) x 140 mm (5.51 in)

E.  

12.75 mm (0.50 in) x 175 mm (6.89 in)

Discussion 0
Question # 20

Which of the following is NOT provided by the ac grounding electrode system?

Options:

A.  

Zero volt reference for AC power

B.  

A path for dissipating electrical current

C.  

A path for dissipating electrostatic discharge

D.  

Adequate electrical protection for people and equipment

Discussion 0
Question # 21

Certain systems must exist relative to bonding and grounding at every site. Which of the following is NOT one such system?

Options:

A.  

AC grounding electrode system (e.g., in some countries it may also be known as the earthing system)

B.  

Telecommunications bonding infrastructure

C.  

Lightning protection system

D.  

Equipment grounding system (e.g., in some countries it may also be known as the equipment bonding system)

Discussion 0
Question # 22

The headend has several audio-video playback devices within it. What piece of equipment is required to assign their output signals to specific RF carriers on the CATV system?

Options:

A.  

Modulator

B.  

Combiner

C.  

Splitter

D.  

Multiport tap

Discussion 0
Question # 23

Exhibit:

Question # 23

The following diagram represents what type of CATV distribution system?

Options:

A.  

Home run

B.  

Trunk and tap

C.  

Video over balanced twisted-pair

D.  

Video over optical fiber

Discussion 0
Question # 24

What is the appropriate impedance of coaxial cable for use with broadband distribution?

Options:

A.  

50

B.  

75

C.  

100

D.  

150

Discussion 0
Question # 25

Which service is NOT typical of Grade 1?

Options:

A.  

Telephone

B.  

Multimedia

C.  

Data

D.  

Television

Discussion 0
Question # 26

You have just finished a design calling for 15 telecommunications outlets. You received word that the owner has increased his requirements by 40%. What size commercial DD (distribution device) is required to accommodate the increase?

Options:

A.  

660 mm (26 in)

B.  

1015 mm (40 in)

C.  

1346 mm (53 in)

D.  

1676 mm (66 in)

Discussion 0
Question # 27

You are designing distribution for a seven unit townhouse with in slab conduits. What is the MINIMUM number of 27 mm (1 in) rigid PVC Type 2 or metallic conduit that is required to satisfy distribution to each unit?

Options:

A.  

Three

B.  

Four

C.  

Five

D.  

Seven

E.  

Fourteen

Discussion 0
Question # 28

Which of the following is NOT a source of electromagnetic interference (EMI)?

Options:

A.  

Copiers

B.  

Transformers

C.  

Incandescent lights

D.  

Fluorescent lights

E.  

Electrical power supply cable

Discussion 0
Question # 29

During a site survey you notice that several CRT displays in the vicinity of the engineering copy center have sporadic visual distortion. What is the MOST likely cause?

Options:

A.  

Electromagnetic interference (EMI)

B.  

Radio frequency interference (RFI)

C.  

(EMC)

D.  

Fast transients

E.  

Electromagnetic discharge (ESD)

Discussion 0
Question # 30

What is the recommended MINIMUM separation of unshielded twisted-pair (UTP) cables from fluorescent light fixtures?

Options:

A.  

77 mm (3 in)

B.  

30 mm (5.12 in)

C.  

203 mm (8 in)

D.  

324 mm (12.75 in)

E.  

483 mm (19 in)

Discussion 0
Question # 31

An isolated ground is used to:

Options:

A.  

Reduce transients

B.  

Prevent interruptions

C.  

Reduce EMI/RFI

D.  

Reduce swells and sags

Discussion 0
Question # 32

A rapid increase in voltage with a duration of half a cycle best describes a(n):

Options:

A.  

Swell

B.  

Overvoltage

C.  

Transient

D.  

Frequency variation

Discussion 0
Question # 33

Phase difference is the relationship in time between two waveforms of the same:

Options:

A.  

Power

B.  

Voltage

C.  

Frequency

D.  

Current

Discussion 0
Question # 34

Geographically speaking, a ______ links two or more distant sites.

Options:

A.  

SAN

B.  

PAN

C.  

LAN

D.  

CAN

E.  

WAN

Discussion 0
Question # 35

The purpose of QoS on an IP network is for:

Options:

A.  

FAX transmission

B.  

Data representation

C.  

Audio quality

D.  

Streaming video quality

E.  

Real time web based services

Discussion 0
Question # 36

Route congestion and message priority are a few of the functions of what layer of the OSI Model?

Options:

A.  

Layer 1

B.  

Layer 2

C.  

Layer 3

D.  

Layer 4

E.  

Layer 5

Discussion 0
Question # 37

In (ESS) design, employees, reputation, and materials are all examples of:

Options:

A.  

Assets

B.  

Risks

C.  

Threats

D.  

Countermeasures

E.  

Systems

Discussion 0
Question # 38

You are designing a strobe visual notification system for a fire alarm system. You have a hallway that is 4.6 m (15 ft) wide and 100 m (328 ft) long. How many strobes should be placed in the hallway?

Options:

A.  

One

B.  

Two

C.  

Three

D.  

Four

E.  

Five

Discussion 0
Question # 39

You are designing an audible alarm notification system for an office environment with an ambient noise level of 55 dB

A.  

What dBA level should the horn be set at?

Options:

A.  

40 dBA

B.  

50 dBA

C.  

55 dBA

D.  

65 dBA

E.  

70 dBA

Discussion 0
Question # 40

Which of the following is NOT a design consideration for broadband video distribution?

Options:

A.  

Amplifier link budgets

B.  

Adhering to the 90 meter (295 feet) rule for horizontal distribution

C.  

Amplifier cascade limitations

D.  

Environmental factors

E.  

Drop length

Discussion 0
Question # 41

The RJ-45 is now known as the 8P8C style connector, per the Telecommunications Industry Association (TIA) standard. What does the P and C stand for?

Options:

A.  

Plug and connector

B.  

Position and connector

C.  

Position and contact

D.  

Plug and contact

Discussion 0
Question # 42

The ability of a conductors insulation to transmit an electric field is called:

Options:

A.  

Conductivity

B.  

Transmitability

C.  

Permittivity

D.  

Capacitance

E.  

Reactance

Discussion 0
Question # 43

Which of the following is NOT a type of connector for optical fiber?

Options:

A.  

LC

B.  

ST

C.  

SFF

D.  

S/FTP

E.  

SC

Discussion 0
Question # 44

A furniture cluster with 26 requires a MINIMUM of how many multiuser telecommunications outlet assembly (MUTOA)?

Options:

A.  

1

B.  

2

C.  

3

D.  

4

E.  

5

Discussion 0
Question # 45

A telecommunications outlet/connector may be provided using all listed below EXCEPT:

Options:

A.  

Wireless AP connectivity

B.  

Balanced twisted-pair outlets

C.  

Optical fiber connectors

D.  

4p4c (4 position, 4 contact) connector

Discussion 0
Question # 46

What is the PERT estimate (in hours) for project design where:

- Optimistic time is 40 hours

- Most likely time is 50 hours

- Pessimistic time is 60 hours

Options:

A.  

40 hours

B.  

45 hours

C.  

50 hours

D.  

55 hours

E.  

60 hours

Discussion 0
Question # 47

All of the following are true about the post construction phase EXCEPT:

Options:

A.  

The owner is responsible to update the record copy drawings to reflect "as-built" documents.

B.  

The contractors are resolving issues identified on the punch lists.

C.  

The architect is involved in final acceptance and contract closeout activities.

D.  

The construction manager is coordinating removal of construction equipment and job trailers.

Discussion 0
Question # 48

At the end of the third week of a project, the actual cost of work performed is $7000 USd and the budgeted cost of work performed is $8000 USd. Which of the following is true?

Options:

A.  

The project is under budget.

B.  

The project is budget incorrect.

C.  

The project has been back-end loaded.

D.  

The project is over budget.

Discussion 0
Question # 49

You are reviewing a building backbone design with a vertically aligned telecommunications room (TR). In the spec you note in a footnote with details that the slots at one end of the telecommunications room (TR) must be flush with the floor and the sleeves provide at the end of the telecommunications room (TR) must also be flush. In your meeting with the electrical engineering firm that has provided the spec, you make the comment that according to best practices, the MINIMUM that slots and sleeves must extend above the finished floor are:

Options:

A.  

25 mm (1 in) for slots and 51 mm (2 in)

B.  

25 mm (1 in) for slots and 25 mm (1 in)

C.  

51 mm (2 in) for slots and 25 mm (1 in)

D.  

51 mm (2 in) for slots and 51 mm (2 in)

E.  

64 mm (2 1/2 in) for slots and 64 mm (2 1/2 in)

Discussion 0
Question # 50

The decision regarding the number of optical fibers to install (fiber strand count) in a backbone depends largely on all of the following EXCEPT:

Options:

A.  

Level of multiplexing

B.  

Intended end-user applications

C.  

Physical topology of the cabling system

D.  

Distance between telecommunications room (TR)

E.  

Cabling system configuration

Discussion 0
Question # 51

You are given a choice of methods of routing backbone cabling vertically through a building. The one option that you do NOT want to use is:

Options:

A.  

Open shafts

B.  

Metallic raceways

C.  

Slots

D.  

Sleeves

E.  

Elevator shafts

Discussion 0
Question # 52

Using the sound pressure level (SPL) method of approximating distance and power, calculate the power required to produce 89 dB at 4 m (13.1 ft) with a loud speaker that is rated at a SPL of 95 d

B.  

What input power level (in watts) is required to appropriately power the speaker?

Options:

A.  

1 watt

B.  

2 watts

C.  

4 watts

D.  

8 watts

Discussion 0
Question # 53

What are the three typical voltages used in centrally amplified paging systems?

Options:

A.  

24, 48, and 90

B.  

25, 70, and 100

C.  

25, 90, and 120

D.  

48, 90, and 120

Discussion 0
Question # 54

A properly designed distributed paging system will provide a sound pressure level (SPL) for audio paging that is between ________ above ambient noise level.

Options:

A.  

3 dB and 6 dB

B.  

6 dB and 10 dB

C.  

10 dB and 20 dB

D.  

20 dB and 55 dB

Discussion 0
Get RCDD-002 dumps and pass your exam in 24 hours!

Free Exams Sample Questions