Winter Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65pass65

Free LEED AP Building Design + Construction (LEED v5 AP BD+C) Practice Questions

Question # 31

When designing for operational decarbonization, a recommended practice when specifications call for refrigerants with a Global Warming Potential (GWP) above 700 is to develop a list of equipment options using:

Options:

A.  

Refrigerants with a GWP less than or equal to 700

B.  

Reclaimed refrigerants with a GWP less than or equal to 700

C.  

Refrigerants with higher volumetric capacity to keep their GWP impact less than or equal to 700

Discussion 0
Question # 32

Which of the following strategies is allowed under Energy Atmosphere Credit, Renewable Energy Production, and will help a project achieve Energy Atmosphere Credit, Optimize Energy Performance?

Options:

A.  

Install an on-site photovoltaic array

B.  

Purchase Green-e certified carbon offsets

C.  

Purchase Green-e certified Renewable Energy Certificates (RECs)

D.  

Install a ground-source heat pump

Discussion 0
Question # 33

Which of the following methods is the referenced standard for demonstrating compliance with Indoor Environmental Quality Prerequisite, Minimum Indoor Air Quality Performance?

Options:

A.  

ASHRAE 62.2 - 2007

B.  

ASHRAE 90.1 - 2010

C.  

ASHRAE 55 - 2010

D.  

ASHRAE 62.1 - 2010

Discussion 0
Question # 34

Selecting a high-reflectance interior paint which is compliant with South Coast Air Quality Management District (SCAQMD) Rule 1113 can help contribute towards which two credits?

Options:

A.  

Indoor Environmental Quality Credit, Low-Emitting Materials and Indoor Environmental Quality Credit, Interior Lighting

B.  

Indoor Environmental Quality Credit, Low-Emitting Materials and Sustainable Sites Credit, Site Assessment

C.  

Indoor Environmental Quality Credit, Low-Emitting Materials and Indoor Environmental Quality Credit, Minimum Indoor Environmental Quality Performance

D.  

Indoor Environmental Quality Credit, Enhanced Indoor Environmental Quality Strategies and Indoor Environmental Quality Prerequisite, Minimum Indoor Environmental Quality Performance

Discussion 0
Question # 35

The required minimum scope of analysis for a product-specific declaration that contributes toward Materials and Resources Credit, Building Product Disclosure and Optimization - Environmental Product Declarations, Option 1. Environmental Product Declaration is

Options:

A.  

gate-to-gate

B.  

cradle-to-gate

C.  

cradle-to-grave

D.  

cradle-to-cradle

Discussion 0
Question # 36

Which of the following ventilation strategies is essential for maintaining acceptable indoor air quality while balancing energy use?

Options:

A.  

Natural ventilation through operable windows

B.  

Mechanical ventilation with heat recovery

C.  

Underfloor air-distribution systems

Discussion 0
Question # 37

A new commercial building is being designed to use small capacity air handling units. To meet the requirements of the Carbon Dioxide Monitoring strategy in the Indoor Environmental Quality Credit, Enhanced Indoor Environmental

Quality Strategies, where would CO2 monitors need to be located?

Options:

A.  

In each occupied space

B.  

In each densely occupied space

C.  

In each occupied space and outdoors

D.  

In each occupied space over 500 ft2 (46 m2)

Discussion 0
Question # 38

Which of the following is a strategy to reduce waste produced by a project?

Options:

A.  

Design-build

B.  

Material reuse

C.  

Alternative daily cover

D.  

Custom design

Discussion 0
Question # 39

When measuring sound pressure levels in a classroom to determine compliance with the HVAC background noise requirements of LEED Building Design and Construction: Schools, Indoor Environmental Quality Prerequisite, Minimum Acoustic Performance, what testing conditions are appropriate for the classroom?

Options:

A.  

Furnished, teacher speaking, HVAC operating at maximum flow rates

B.  

Unfurnished, teacher speaking, HVAC operating at typical level

C.  

Furnished, no occupants, HVAC operating at typical level

D.  

Unfurnished, no occupants, HVAC operating at maximum flow rates

Discussion 0
Question # 40

Major renovation projects must meet which of the following minimum percentage savings when taking credit for renewable energy systems?

Options:

A.  

5%

B.  

3%

C.  

2%

D.  

8%

Discussion 0

LEED-AP-BD+C PDF

LEED-AP-BD+C PDF (Printable)
$54.25
$154.99

LEED-AP-BD+C Testing Engine

LEED-AP-BD+C PDF (Printable)
$59.5
$169.99

LEED-AP-BD+C PDF + Testing Engine

LEED-AP-BD+C PDF (Printable)
$74.55
$212.99

Free Exams Sample Questions