Pre-Winter Sale Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 65pass65

Free LEED AP Building Design + Construction (LEED v5 AP BD+C) Practice Questions

Exams4sure Dumps

Exam style questions across every LEED-AP-BD+C domain

Last Update 2 days ago
Total Questions : 442

Start with our free LEED-AP-BD+C practice questions, carefully crafted to mirror the domains, phrasing, and difficulty of the real Leadership in Energy and Environmental Design (LEED) exam. Each LEED-AP-BD+C exam question comes with a detailed rationale that explains not just which answer is correct but why the others fall short. That's how concepts stick. Use the free set to benchmark yourself: identify your USGBC weak domains, see where you're losing marks, and build a focused study plan in minutes.

LEED-AP-BD+C PDF

LEED-AP-BD+C PDF (Printable)
$54.25
$154.99

LEED-AP-BD+C Testing Engine

LEED-AP-BD+C PDF (Printable)
$59.5
$169.99

LEED-AP-BD+C PDF + Testing Engine

LEED-AP-BD+C PDF (Printable)
$74.55
$212.99
Question # 41

A request to change the lighting fixtures in a conference room is made by a tenant. Which of the following credit scorecard changes will be directly and indirectly impacted by the change in lighting fixtures?

Options:

A.  

Indoor Environmental Quality Credit, Interior Lighting and Sustainable Sites Credit, Light Pollution Reduction

B.  

Energy and Atmosphere Credit, Optimize Energy Performance and Indoor Environmental Quality Credit, Interior Lighting

C.  

Energy and Atmosphere Credit, Advanced Energy Metering and Indoor Environmental Quality Credit, Daylight

D.  

Indoor Environmental Quality Credit, Thermal Comfort and Indoor Environmental Quality Credit, Enhanced Indoor Air Quality Strategies

Discussion 0
Question # 42

Which of the following transit modes is considered to be walkable if it is within 1/2 mile (0.8 km) of the functional entry of a project?

Options:

A.  

Taxi stand

B.  

Ferry terminal

C.  

Local bus stop

D.  

Streetcar stop

Discussion 0
Question # 43

A project will renovate a building with historic designation into new office space. The surface area of the existing building structure and envelope is 100,000 ft² (9,290 m²). How much of the existing building will need to be reused to earn 5 points for the Materials and Resource Credit, Building Life-Cycle Impact Reduction?

Options:

A.  

90,000 ft² (8,361 m²)

B.  

There is no minimum

C.  

80,000 ft² (7,432 m²)

D.  

At least 50% of the surface area

Discussion 0
Question # 44

When using the Integrative Process, what is the best way for the LEED AP to assess the impact of indoor and outdoor water consumption in a Building Design and Construction project?

Options:

A.  

Perform a preliminary water budget analysis before the completion of schematic design

B.  

Install permanent metering on both the water sources and the waste water leaving the site

C.  

At the completion of schematic design, count the fixtures and apply the maximum flow rate

D.  

Estimate consumption by using 20 gal. per day (76 I per day) for each Full Time Equivalent (FTE) scheduled to occupy the building

Discussion 0
Question # 45

Sustainable Sites Credit, Site Assessment requires evaluation of

Options:

A.  

soils, archeology, hydrology

B.  

topography, hydrology, human use

C.  

vegetation, topography, archaeology

D.  

human health effects, climate, land value

Discussion 0
Question # 46

Which strategy should be employed to improve daylighting when designing a new building?

Options:

A.  

Increase the building depth

B.  

Increase the number of skylights

C.  

Increase the height of interior partitions

D.  

Decrease the number of exterior light shelves

Discussion 0
Question # 47

Which of the following is a source reduction strategy to eliminate waste produced by a project?

Options:

A.  

Custom design

B.  

Design-build

C.  

Material science

D.  

Prefabrication

Discussion 0
Question # 48

What phase of the integrative process gives the team the greatest chance of success in meeting the project ' s environmental goals cost-effectively?

Options:

A.  

Design

B.  

Discovery

C.  

Operations

D.  

Construction

Discussion 0
Question # 49

A Core and Shell developer pursuing the IPc2 Green Leases credit has drafted lease language. Which provision meets the intent of the credit for binding tenant sustainability commitments?

Options:

A.  

Tenant shall submit quarterly energy and water consumption reports and achieve a minimum 50% waste diversion rate verified through waste hauler documentation.

B.  

Owner will provide tenant with LEED design guidelines and green building best-practices handbook within 30 days of lease execution for reference.

C.  

Tenant acknowledges that the building has achieved LEED certification and agrees to maintain awareness of sustainable building operations during occupancy.

Discussion 0
Question # 50

A project ' s installed water fixtures do not exceed WaterSense maximum levels. Which compliance path should the LEED AP select under Water Efficiency Prerequisite, Indoor Water Use Reduction, and what type of documentation is required to demonstrate compliance with this path?

Options:

A.  

Compliance Path 2: Usage-Based Calculation; prescriptive compliance confirmation

B.  

Compliance Path 2: Usage-Based Calculation; appliance water calculations

C.  

Compliance Path 1: Prescriptive Achievement; indoor water use calculations

D.  

Compliance Path 1: Prescriptive Achievement; product cutsheets

Discussion 0

Free Exams Sample Questions